GDS Gas Dilution System
The sampler and dilution unit are in a single cabin. Flow control of
both units is done with two independent mass flow meters integrated into the device. Total and dilution gas volume can measure with two independent dry gas meter. All of this process is automatic and controlled by the device's microprocessor.
The two streams are regulated independently, so for different stack
condition the dilution ratio can be changed indepandantly. The
temperatures inside both dry gas meters reads with two tempreture
sensor and stores in the memory of the sampler.
The dilution and total sample inlets are equipped with two easily replaceable cartridges. In addition, the user can easily replace the cartridge silica gel and charcoal. Unlike traditional manual sampler, it is fully automated. Dilution and total flow rates can be adjusted digitally. The sampler automatically controls the set flow rates and adjusts the flow rates. The sampler also directly reads gas volumes and temperatures from the dry gas meter. Thus, it is not necessary to note the first and last readings and temperatures from the dry gas meter.
Total Sampled Volume
Gas Meter Class | Gas Meter Class Dry Gas Meter, class G4, certified 2004/22/CE, in compliance to EN 1359 |
Flowrate range | 0.016 m3/h ÷ 2.5 m3/h |
Accuracy | 2% |
Encoder resolution | 0.02 liters |
Dilution Sampling Flowrate
Device | Flowmeter in compliance with UNI EN ISO 5167-2 |
Range | 0.1 ÷ 1.2 l/min |
Accuracy | Better than ± 1% |
Resolution | 0.01 l/min |
Total Sampling Flowrate
Device | Flowmeter in compliance with UNI EN ISO 5167-2 |
Range | 0.1 ÷ 1.2 l/min |
Accuracy | Better than ± 1% |
Resolution | 0.01 l/min |
ABS, Pressure(Static or Barometric)
Range | 0 ÷ 105 kPa (1050 mBar) |
Accuracy | Better than 1% of measure ± 0.01 kPa |
Resolution | 0.01 kPa (0.1 mBar) |
Tempreature: (Programmed Curve Type "K" as per ITS 1990)
Range | 0 ÷ 1200 °C |
Accuracy | 1% of measure (± 0.2 °C) |
Resolution | 0.1 °C |
DGM Temperature (PT100 Sensor)
Range | -20 ÷ 80 °C |
Accuracy | 1% (± 0.2) |
Resolution | 0.1 °C |
Flowrate operative range | 0.1 ÷ 1.2 l/min |
Sampled gas conditions | Dehydrated, max temperature 45°C |
Total Gas inlet | With protection filter and silicagel cartridge for particulate and liquids |
Connection | With quick connectors |
Operation conditions | - 20 ÷ 40°C 95% UR |
Stock conditions | - 10 ÷ 50°C 95% UR |
Display | 5.0” Graphic Color |
Keyboard | Polycarbonate, tactile effect keys |
Data Port | USB 2.0 |
Printer Port | Bluetooth |
Internal Memory | 16GB |
Power supply | 220 Vac ±10% 50/60Hz |
Materials | % 100 Aluminum |
Dimensions | 395 x 262 x 502 mm (W x D x H) |
Weight | 10 kg |
- Precise sampling flowrate is directly controlled with a mass flow meter
- Higher quality of the data due to automated parameters control
- It's possible to enter and set the dilution and totale sample flowrate
- Total sampel gas inlet protected by removeble silicagel cartridge
- Removeble charcoal cartridge for zero gas outlet
- 3 independent colored thermocouple inputs
- Large color screen
- Easy installation of interconnection socket entries