The ECO model of ISO Smart dust and gas sampler has been designed and developed in accordance with international standards for sampling stack emissions.
The sampler is equipped with three thermucuple inputs for flue gas temperature, heated sampling probe and filter holder temperature measurement and control.
Flue gas velocity measurement takes place with a pitot tube. The measured flue gas velocity is evaluated by the microprocessor and provides isokinetic sampling. Total gas volume of the sampler is measured by the dry gas meter. All measured parameters are stored in the device memory. All of this process is automatic and controlled by the device microprocessor.
The sampler composed by two units, the Control Unit and the Pump Unit. In this version, the user only moves the lightweight control unit to the sampling point. It does not need to move the heavy pump unit to the measuring point. It is possible for this sampler to keep this unit on the ground.
Diffrential Pressure
dP Pitot | -100 ÷ 1000 Pa (-10÷100 mmH₂O) |
Accuracy | Better than 1% of measure ± 2Pa |
Resolution | 0.1 Pa (0.01 mmH2O) |
ABS, Pressure(Static or Barometric)
Range | 0 ÷ 105 kPa (1050 mBar) |
Accuracy | Better than 1% of measure ± 0.01 kPa |
Resolution | 0.01 kPa (0.1 mBar) |
Tempreature: (Programmed Curve Type "K" as per ITS 1990)
Range | 0 ÷ 1200 °C |
Accuracy | 1% of measure (± 0.2 °C) |
Resolution | 0.1 °C |
DGM Temperature (PT100 Sensor)
Range | -20 ÷ 80 °C |
Accuracy | 1% (± 0.2) |
Resolution | 0.1 °C |
Sampled Volume
Gas Meter Class | Gas Meter Class Dry Gas Meter, class G4, certified 2004/22/CE, in compliance to EN 1359 |
Flowrate range | 0.04 m3/h ÷ 6.0 m3/h |
Accuracy | 2% |
Encoder resolution | 0.02 liters |
Sampling Flowrate
Device | Flowmeter in compliance with UNI EN ISO 5167-2 |
Range | 5 ÷ 60 l/min |
Accuracy | Better than ± 1% |
Resolution | 0.01 l/min |
Flowrate operative range | 5 ÷ 60 l/min |
Sampled gas conditions | Dehydrated, max temperature 45°C |
Gas inlet | With protection filter for particulate |
Connection | With quick connectors |
Operation conditions | - 20 ÷ 40°C 95% UR |
Stock conditions | - 10 ÷ 50°C 95% UR |
Display | 5.0” Graphic Color |
Data Port | USB 2.0 |
Printer Port -Optional | Bluetooth |
Internal Memory | 16GB |
Power supply | 220 Vac ±10% 50/60Hz |
Materials | % 100 Aluminum |
Keyboard | Polycarbonate, tactile effect keys |
Dimensions | Main Unit: 395 x 262 x 350 mm; Pump: 395 x 262 x 150 mm (W x D x H) |
Weight | Main Unit: 7 kg ; Pump: 8 kg |
- Precise isokinetic condition, sampling flowrate is directly controlled with a mass flow meter
- Higher quality of the data due to automated parameters control
- It can work with all Pitot tubes and thermocouples
- It's possible to enter the information related to Pitot tubes in the internal library
- 3 independent colored thermocouple inputs
- Large color screen
- Isokinekik and constant flow
- Easy installation of interconnection socket entries